▌General Information

The external display DM-F2-VA is detached from the DC meter to display the meter values independent from the meter’s physical position inside the system. It is connected to the meter via a secure data line. The meter will be checked for a correct connection cyclically at any time.

DM-F2-VA Display interface
DM-F2-VA Display interface

 

The display shows billing relevant data for a charging process as well as other information.

Drawing

DM-F2-VA External Display
DM-F2-VA External Display

▌Installation

The connection between the external display and the meter is realized by a RS485 line connected to the RS485 ports.

Connection between display module and GSH01 meter
Connection between display module and GSH01 meter

Physical Interfaces

DM-F2-VA External Display
DM-F2-VA External Display

Serial number

Item

Description

2PIN interface (from left to right)

1

Power input + DC12V-36V

2

Power input –

4PIN interface (from left to right)

1

· Power input + The output voltage is the same as the power input.

Used for connecting the power input of the electricity meter.

2

· Power input –

3

RS485-A Used for connecting to any RS485 port.

4

RS485-B